mgeeky-Penetration-Testing-.../phishing/MacroDetectSandbox.vbs

140 lines
4.0 KiB
Plaintext
Raw Normal View History

2018-02-02 22:22:43 +01:00
Private Declare PtrSafe Function isDbgPresent Lib "kernel32" Alias "IsDebuggerPresent" () As Boolean
Public Function IsFileNameNotAsHexes() As Boolean
Dim str As String
Dim hexes As Variant
Dim only_hexes As Boolean
only_hexes = True
hexes = Array("0", "1", "2", "3", "4", "5", "6", "7", _
"8", "9", "a", "b", "c", "d", "e", "f")
str = ActiveDocument.name
str = Mid(str, 1, InStrRev(str, ".") - 1)
For i = 1 To UBound(hexes, 1) - 1
Dim ch As String
ch = LCase(Mid(str, i, 1))
If Not (UBound(Filter(hexes, ch)) > -1) Then
' Character not in hexes array.
only_hexes = False
Exit For
End If
Next
only_hexes = (Not only_hexes)
IsFileNameNotAsHexes = only_hexes
End Function
Public Function IsProcessListReliable() As Boolean
Dim objWMIService, objProcess, colProcess
Dim strComputer, strList
Dim bannedProcesses As Variant
bannedProcesses = Array("fiddler", "vxstream", _
"tcpview", "vmware", "procexp", "vmtools", "autoit", _
"wireshark", "procmon", "idaq", "autoruns", "apatedns", _
"windbg")
strComputer = "."
Set objWMIService = GetObject("winmgmts:" _
& "{impersonationLevel=impersonate}!\\" _
& strComputer & "\root\cimv2")
Set colProcess = objWMIService.ExecQuery _
("Select * from Win32_Process")
For Each objProcess In colProcess
For Each proc In bannedProcesses
If InStr(LCase(objProcess.name), LCase(proc)) <> 0 Then
' Found banned process.
IsProcessListReliable = False
Exit Function
End If
Next
Next
If isDbgPresent() Then
IsProcessListReliable = False
Exit Function
End If
IsProcessListReliable = (colProcess.Count() > 50)
End Function
Public Function IsHardwareReliable() As Boolean
Dim objWMIService, objItem, colItems, strComputer
Dim totalSize, totalMemory, cpusNum As Integer
totalSize = 0
totalMemory = 0
cpusNum = 0
Const wbemFlagReturnImmediately = &H10
Const wbemFlagForwardOnly = &H20
strComputer = "."
' Checking total HDD size
Set objWMIService = GetObject _
("winmgmts:\\" & strComputer & "\root\cimv2")
Set colItems = objWMIService.ExecQuery _
("Select * from Win32_LogicalDisk")
For Each objItem In colItems
Dim num
num = Int(objItem.Size / 1073741824)
If num > 0 Then
totalSize = totalSize + num
End If
Next
If totalSize < 60 Then
' Total HDD size of the machine must be at least 60GB
IsHardwareReliable = False
Exit Function
End If
' Checking Memory
Set colComputer = objWMIService.ExecQuery _
("Select * from Win32_ComputerSystem")
For Each objComputer In colComputer
totalMemory = totalMemory + Int((objComputer.TotalPhysicalMemory) / 1048576) + 1
Next
If totalMemory < 1024 Then
' Total Memory is less than 1GB
IsHardwareReliable = False
Exit Function
End If
Set colItems2 = objWMIService.ExecQuery("SELECT * FROM Win32_Processor", "WQL", _
wbemFlagReturnImmediately + wbemFlagForwardOnly)
For Each objItem In colItems2
cpusNum = cpusNum + objItem.NumberOfLogicalProcessors
Next
If cpusNum < 2 Then
' Nowadays everyone has at least 2 logical cores.
IsHardwareReliable = False
Exit Function
End If
IsHardwareReliable = True
End Function
Public Function IsRunningInSandbox() As Boolean
Dim test As Boolean
If IsFileNameNotAsHexes() <> True Then
IsRunningInSandbox = True
Exit Function
ElseIf IsProcessListReliable() <> True Then
IsRunningInSandbox = True
Exit Function
ElseIf IsHardwareReliable() <> True Then
IsRunningInSandbox = True
Exit Function
End If
IsRunningInSandbox = False
End Function